HP Intelligent Power
HP Intelligent Power
HP Intelligent Power
HP Intelligent Power
Distribution Units
Distribution Units
Distribution Units
Distribution Units (iPDU)
iPDU Core Units
iPDU Core Units
iPDU Core Units
iPDU Core Units
HP 17.3kVA 24A 415V Three Phase L22-30 Core Intelligent Power Distribution Unit
AF902A
HP 17.3kVA 24A 415V Three Phase IEC309 Core Intelligent Power Distribution Unit
AF901A
HP 4.9kVA 24A Single Phase Core Intelligent Modular Power Distribution Unit
AF520A
HP 8.6kVA 24A Three Phase Core Intelligent Modular Power Distribution Unit
AF522A
HP 11.4kVA 16A 415V Three Phase L22-20 Core Intelligent Power Distribution Unit
AF900A
NOTE:
NOTE:
NOTE:
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
 
HP Rack Series
HP Rack Series
HP Rack Series
HP Rack Series
Rack 10000 G2 Series
Rack 10000 G2 Series
Rack 10000 G2 Series
Rack 10000 G2 Series
HP 10642 G2 1200mm deep Shock Rack
AF092A
HP 10647 G2 1200mm deep Shock Rack
AF094A
HP 10642 G2 Pallet Universal Rack
AF001A
HP 10642 G2 Shock Universal Rack
AF002A
NOTE:
NOTE:
NOTE:
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: 
 
HP Rack Options
HP Rack Options
HP Rack Options
HP Rack Options
HP KVM Switches
HP KVM Switches
HP KVM Switches
HP KVM Switches
HP Server Console 0x2x8 Port Analog Switch
AF616A
HP Server Console 0x2x16 Port Analog Switch
AF617A
NOTE:
NOTE:
NOTE:
NOTE: Please see the QuickSpecs for Technical Specifications and additional
information:
 
HP 1x4 USB/PS2 KVM Console Switch
AF611A
Rack 10000 G2 series Cabinets
Rack 10000 G2 series Cabinets
Rack 10000 G2 series Cabinets
Rack 10000 G2 series Cabinets
The increasing power of new high-performance processor technology requires
increased cooling efficiency for rack-mounted servers. The 10000 G2 Series Racks
provide enhanced airflow for maximum cooling, allowing these racks to be fully
loaded with servers using the latest processors.
CAUTION:
CAUTION:
CAUTION:
CAUTION: If a third-party rack is used, observe the following additional requirements
to ensure adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors,
you must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top
to bottom to permit adequate airflow (equivalent to the required 64 percent open
area for ventilation).
Side: The clearance between the installed rack component and the side panels of the
rack must be a minimum of 7 cm (2.75 inches)
CAUTION:
CAUTION:
CAUTION:
CAUTION: Always use blanking panels to fill all remaining empty front panel U-
spaces in the rack. This arrangement ensures proper airflow. Using a rack without
blanking panels results in improper cooling that can lead to thermal damage.
 
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
HP ProLiant DL160 Generation 6 (G6)
Additional Options
DA - 13247   North America — Version 50 — October 10, 2011