CISPR 24 Immunity Phenomena
Basic Standard
Test Specification
Electrostatic Discharge 
IEC 61000-4-2:1995
6 kV Contact, 10 kV Air
Radio-Frequency Electromagnetic 
Field (radiated)
IEC 61000-4-3:1995
80-1000 MHz, 3 V/m, 80% AM 
@ 1 KHz 
Fast Burst Transients 
IEC 61000-4-4:1995
5/50 Tr/Th ns, 5 kHz Rep. Freq
     0.5 kV Signal Lines 
     1 kV AC Mains
Line Surge            
IEC 61000-4-5:1995
Combination wave
   2.0 kV Common mode
   2.0 kV Differential mode
Radio-Frequency Electromagnetic 
Field (Conducted)
IEC 61000-4-6:1996
0.15 - 80 MHz, 3 V, 80% AM @ 1 kHz
 Line voltage dips
IEC 61000-4-11:1994
>95% dip for Ѕ cycle @ 50 Hz 
 30% dip for 25 cycles @ 50 Hz 
Line voltage drop-out
IEC 61000-4-11:1994