Xerox DocuTech 6100 Production Publisher User Guide

Page of 34
 
Changing the Retain PDL Setting 
Perform the following steps to modify the number of PDLs that can 
be retained on the DocuSP. 
1.  On the DocuSP interface, select Setup and System 
Preferences. Select the Job Policy tab. 
2.  Ensure that the setting for Retain PDL files of last 50 jobs is set 
as enabled. 
3.  Select [OK]. Do not restart the system if you are prompted to do 
so. 
4.  In the background, right-click to open the menu. Open a 
terminal window. 
5.  Login as root user. 
6.  Type: /opt/XRXnps/bin/setretainPDL # and press <Enter>, 
where # is a number between 1 and 100. A value of 0 
maintains the current setting. 
7.  Close the terminal window. Restart the DocuSP software. 
 
Reset the Xrite Spectrophotometer 
Perform the following to reset the spectrophotometer: 
Ensure that the calibration strip that matches the serial number on 
the spectrophotometer is available. If not, order a new one before 
continuing. 
1.  On the DocuSP controller background menu, open a terminal 
window. 
2.  At the % prompt, type: 
cd /opt/XRXnps/XRXcalLib/bin 
3.  From the % prompt, type: 
. /resetDTP 
This will restore the spectrophotometer to the factory default 
settings.
 
After the reset is complete, follow the standard procedure to 
calibrate the spectrophotometer using the Xrite calibration strip. 
 
24