Stock Management and Calibration
3-4
Color Management Guide
Calibrating the DocuColor 2045/2060/6060 family
For the DC 2045/2060 and 6060, you should calibrate at least 
once or twice a day or more often when printing jobs that are 
“color-critical.”
The default number of prints of the calibration targets is 5 for the 
DC 2045/2060/6060 family. However, you may choose to print as 
many as 200 calibration targets at one time; we recommend 
printing 5 prints (of the 2-page target) and then choosing the 5th 
print to use for calibration.
Calibrating the DocuColor iGen3
Calibration should be performed at least once per color group, 
per halftone per eight hour shift for the DocuColor iGen3.
For example, if jobs to be printed during the night shift require 
Stock A using 175 dot halftone for job #1 and a 200 dot halftone 
for job #2, a calibration is needed for Stock A at 175 dot and at 
200 dot. 
These calibrations are assigned to Stock A with a 175 dot 
halftone and Stock A with a 200 dot halftone. 
When calibrating 8.5 x 11 - A4 stock print 40 single sided copies 
of the (2-page) target. For larger sized stock print 20 single sided 
copies of the target; we recommend using the final print for 
calibration.
Calibration target tips
DocuSP calibration software checks the first color at the top of 
each calibration strip as a method of insuring that strips 1-13 are 
read in the correct order. If the top color is not detected, or is 
detected improperly, calibration fails. Due to image-to-page top 
variation associated mainly with the iGen3 engine, calibration 
errors can occur if you pushes the target too far into the 
Spectrophotometer. 
Primarily, this can occur using the 11”x17” calibration targets, 
which must be cut down manually to 8.5”x17” in order to feed 
correctly into the X-Rite. This introduces the image-to-page top 
variation previously mentioned.
This section provides pictorial instructions for successful 
calibration in spite of target image location fluctuation on the 
calibration target.