3-10
Color Calibration
3.
Select a measurement method.
AutoCal2 and X-Rite DTP32 should appear as the measurement methods. This 
information is provided to Calibrator by the Fiery. If neither option appears, make 
sure you are connected to the Fiery.
4.
Under Check Print Settings, choose the desired calibration set.
Choose the appropriate calibration set for the type of media you will use most often. 
N
OTE
:
For this calibration to take effect, the calibration set must be associated with one 
or more output profiles. The default calibration set is already associated with the 
default output profile, so there is no need to make any new associations.
5.
Under Generate Measurement Page, click Print.
6.
In the Print Options dialog box that appears, choose the page type, paper size, and 
input tray to use for the measurement page and click Print.
For AutoCal2, the Page Type pop-up menu states AutoCal Page. For the densitometer 
method, select either 34 or 21 Sorted Patches.