Honeywell 7-Day Programmable Thermostat (RTH7600D) Owner's Manual

Page of 40
11
Function  Description 
Setting 
Press the s or t button to change the setting.
0170
Select System Type
1
  Heat/cool: Gas, oil or electric heating with central air 
conditioning.
2
  Heat pump: Heat pump without backup or auxiliary heat.
3
  Heat only: Gas, oil or electric heat without central air 
conditioning.
4
  Heat only with fan: Gas, oil or electric heat without central air 
conditioning.
5
  Hot water heat only (no fan): Gas, oil or hot water heat 
without central air conditioning.
6
  Cool only: Central air conditioning only.
7
  Heat pump: Heat pump with backup or auxiliary heating.
8
  Heat/Cool Multiple stages: 2 heat stages (wires on W and 
W2), 2 cooling stages (wires on Y and Y2).
9
  Heat/Cool Multiple stages: 2 heat stages (wires on W and 
W2), 1 cooling stage (wire on Y).
10
 Heat/Cool Multiple stages: 1 heat stage (wire on W), 2 
cooling stages (wires on Y and Y2).
0180
Heating Fan Control
0
  Gas or oil heat: Use this setting if you have a gas or oil 
heating system (system controls fan operation).
1
  Electric heat: Use this setting if you have an electric heating 
system (thermostat controls fan operation).
0190
Heat Pump Changeover Valve 
(for heat pumps only)
0
  Cooling changeover valve: Use this setting if you connected 
1
  Heating changeover valve: Use this setting if you connected 
0240
Heating Cycle Rate
5
  Gas or oil furnace: Standard gas/oil furnace (less than 90% 
efficiency).
9
  Electric furnace: Electric heating systems.
3
  Heat pump, hot water or high-efficiency furnace: Hot water 
system or gas furnace (more than 90% efficiency).
1
  Gas/oil steam or gravity system: Steam or gravity heat 
systems.
Settings 5, 9, 3, or 1 recommended. Other settings: 2, 4, 6, 7, 
8, 10, 11, 12. The number indicates how frequently the system 
cycles on and off to maintain the set temperature. A higher 
number means the system is on and off for shorter amounts 
of time, a lower number means longer on and off times. When 
these settings are set to match the system type, the thermostat 
controls temperature more accurately.
0270
Emergency Heat Cycle Rate 
(heat pumps only)
9
  Electric furnace: Electric heating systems.
0300
Manual/Auto Changeover
0
  Manual changeover (Heat/Cool/Off).
1
  Automatic changeover (Heat/Cool/Auto/Off). Automatically 
turns on Heat or Cool based on room temperature. Note: 
System maintains minimum 3°F difference between heat and 
cool settings.
0320
Temperature Format (°F/°C)
0
 Fahrenheit
1
 Celsius
0330
Daylight Saving Time On/Off
0
  Off: No adjustment for daylight saving time.
1
  On: Auto-change to daylight saving time (for areas that do 
not use the new 2007 DST calendar).
2
  On: Auto-change to daylight saving time (2007 and beyond, 
for areas that use the new 2007 DST calendar).