Antler 500AP24SAFA Leaflet

Page of 1
Antler Europe BV
Atronic Technology
C/Metal, 16 P.I. San José de Valderas
28918 Leganés (Madrid), Spain
Tel:+34 902 167 888 Fax:+34 916 436 897
www.antler-group.com
Complies with ATX12V / EPS 12V
90~264 Vac Universal
Thermal Fan-speed Control
With 120*120* 25mm Cooling fan
Dimension: 150(L)x140(W)x86(H)mm
Dual S-ATA
www.antler-group.com
Environmental
Operating temperature: 5ºC to 40ºC
Storage temperature: -20ºC to 70ºC
MTBF: > 50,000hrs at 80% load, 25ºC ambient
Input range: 90V~264Vac
Frequency: 47~63Hz.
Input Current: 500W 10A / 6A FOR 115/230 Vac.
Efficiency: 80% at full load, nominal line.
Inrush current: The maximum inrush current shall be less
than 60A peak from a cold start at any line voltage.
Max.:500W
Hold up time: >12ms at full load, nominal line.
Rise time: <20ms at full load, nominal line.
Over voltage protection: +3.3V, +5V, +12V. Over power
protection: 120-160%. Short circuit: Latch Off.
Power good signal: TTL compatible.
EMI/RFI
SAFETY
Input
Output
Electrical
Specification
+3.3V:3.14V~3.47V == ±5%
+12V1:11.4V~12.6V == ±5%
-12V:-10.8V~-13.2V == ±10%
+3.3V == 150mVp-p
+12V1 == 200mVp-p
-12V == 200mVp-p
Complies with ATX12V / EPS 12V90~264 Vac
CUL,TUV,CB,CSA,DEMKO,NEMKO,SEMKO,FIMKO
Output
Output
I min.
I max.
I peak
+5V & +3.3V combined load
+5V & +3.3V & +12V combined load
Total power rating
REGULATION
Output
RIPPLE &
NOISE(mV)
+3.3V
+5V
+12V1
-12V
+5VSB
1
2
3
4
5
0.8 A
0.5 A
1.0 A
0.0 A
0.0 A
24 A
22 A
18 A
18 A
0,5 A
22 A
22 A
130W
485W
500 W
+5V:4.75V~5.25V == ±5%
+12V2:11.4V~12.6V == ±5%
+5VSB:4.75V~5.25V == ±5%
+5V == 150mVp-p
+12V2 == 200mVp-p
+5VSB == 150mVp-p
+12V2
6
1.0 A
2,0 A
+12V Output Current not exceed
+12V Output Peck Current not exceed
33 A
38 A