Timberk TIM 05 HP4 User Manual

Page of 24
2
www.timberk.com   electric floor standing air  onditioner  ortable type (single case) 
1. IMPORTANT INFORMATION
1.  Please  read  this  instruction  manual  carefully  prior  to  installation  and 
operation of a portable air conditioner.
2.  To  avoid  damage  to  the  air  conditioner  and  voiding  your  guarantee, 
before start using the air conditioner put the device in a vertical position (as 
shown on the cover of this instruction manual) for at least 2 hours prior to 
operation.
3. There may be misprints in the text and digital symbols in this manual.
4.  If  after  reading  the  manual  you  would  still  have  questions  regarding 
functioning  and  operation  of  the  device,  please  contact  the  seller  or  a 
specialized service center for clarifications.
5. The  device  has  a  tag  indicating  all  necessary  technical  data  and  other 
useful information about the device.
6. Use the device only as designated by this manual.
7. Prior to installation of the portable air conditioner, not connecting it to the 
mains, check and make sure that the mains socket for the air conditioner has 
a grounding pin and is properly grounded.
8. In case there is no grounding pin in your mains, operation of the portable 
air conditioner is life-threatening.
Dear Customer!
Thank you for a shrewd choice and purchase of Timberk portable electric air 
conditioner.
It will serve you for a long time.
1.Important information.........................................................................................................
2.Precautions................................................................................................................................
3.Technical characteristics......................................................................................................
4.Description of portable air conditioner......................................................................
5.Control of portable air conditioner.................................................................................
Control panel (for AC TIM 05H P4, AC TIM 07H P4, AC TIM 09H P4).................
Control panel (for AC TIM 09HE P4)....................................................................................
Remote control 
(for AC TIM 09HE P4)...............................................................................
6.Maintenance............................................................................................................................
7.Service life..................................................................................................................................
8.Rules of disposal......................................................................................................................
9.Helpful advice..........................................................................................................................
10.Troubleshooting...................................................................................................................
9. Do not use adapters and extension cords to connect your portable air 
conditioner.
10. Improper installation and use of this air conditioner may lead to severe 
injuries or damage to your property.
11. Any maintenance must be performed by a specialized company and 
qualified specialists.
2. PRECAUTIONS
1. Do not block vents!
2. Make sure the inlet and outlet vent is not blocked.
3. Do not insert foreign objects into the air diffuser of the air conditioner. It is 
very dangerous since the fan rotates at high speed.
4. Install the device only on a horizontal surface to prevent condensed water 
leakage.
5. Do not install the floor-mounted air conditioner in the following places:
- in places exposed to direct sunlight;
- in the vicinity of open fire sources;
- in the vicinity of other operating heating devices;
- in places where water or steam splashes can contact the device;
- in rooms with increased humidity;
- close to swimming pools, bathrooms and shower rooms.
6. Do not use the device in an explosive or corrosive environment. Do not 
store gasoline and other volatile flammable liquids near the air conditioner 
 it is very dangerous!
7. Use the device to cool down air at ambient temperature 17-32°C. To use 
the device as a heater the room temperature must be 5-23°C.
8. Regularly clean filters to ensure efficient operation of the device.
9.  To  ensure  reliable  operation  of  the  compressor,  do  not  tilt  the  air 
conditioner.
10. If the device is disconnected, restarting must be performed not sooner 
than in 3.5 minutes to prevent the compressor failure.
11. At least 10 A current is required for the compressor to operate. To avoid 
overheating and fire risk, as well as damage to the inner electrical circuit, do 
not connect the device through extension cords.
12.  The  device  is  designed  to  cool,  heat  and  dry  air  only  in  residential 
conditions and cannot be used for industrial purposes.
13. To avoid electric shock, a damaged power cord must be replaced only by 
an authorized service center and qualified specialists.
14. Prior to disposal of the device, it is necessary to remove batteries from it, 
after that they can be safely disposed.
 2
 2
 3
 4
 5
 5
 5
  6
  7
  8
  8
  8
10