Dimplex ABU-DABI с очагом Cassette 600 (белый дуб, патина золото) (64906179) User Manual

Page of 56
Symptom
Cause
Corrective Action
The fl ame effect will 
not start.
Mains plug is not plugged in.
Low water level.
 
Low voltage connector not connected 
properly. (See Fig.5)
The Transducer Unit is not sitting correctly in 
the sump
Check plug is connected to wall socket 
correctly.
Check that the water tank is full and there is 
water in the sump.
Check that the connector is inserted 
correctly. (See Fig.5)
Ensure the Transducer in sitting down into 
the moulded recess in the  sump
The fl ame effect is too 
low.
Flame effect control knob is set too low.
(See Fig.10)
The Metal Disc in the transducer might be 
dirty (See Fig.14)
The wire from the Transducer Unit is sitting 
over the metal disc
Increase level of fl ame by turning Control 
knob ‘D’ to the left slowly. (See Fig.10)
Clean the Metal Disc with soft brush 
supplied. (See Fig.14) See ‘Maintenance.’ for 
a step by step procedure.
Direct the wire to the back of the sump and 
make sure it sits into the side slot exiting the 
sump.
Unpleasant smell 
when unit is used.
Dirty or stale water.
Using unfi ltered tap water.
Clean the unit as described under 
maintenance.
Use only fi ltered tap water.
The fl ame effect has 
too much smoke.
Flame effect setting is too high.
Turn the fl ame effect  Control knob ‘D’ to 
the right, about ¼ a turn, at a time. Give the 
fl ame generator some time to adjust to the 
new setting. (See Fig.10)
Main lamps are not 
working and there are 
no fl ames or smoke.
There is no water in the water tank
Follow instructions under 
Maintenance,  ‘Filling the water tank’.
Check the plug is connected to the wall 
socket correctly and that Switch ‘A’ Fig. 10 is 
in the ‘ON’  ( ) position.
Troubleshooting