Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Technical References
6
OL-31229-01
Upgrading the RF Split in the GainMaker 4-Port Node
8 Using a Torx T-10 screwdriver, remove the screws that hold the amplifier board
in place AND the screw holding the Voltage Regulator in place.
9 Remove the amplifier board.
10 Install the new amplifier board being careful to use all the screws removed
10 Install the new amplifier board being careful to use all the screws removed
earlier and tighten the Torx T-10 screws from 5 to 8 in-lb (0.56 to 0.90 Nm).
11 Replace the Reverse Amplifier cover.
12 Configure the RF Amplifier in the same configuration as the one it is intended to
12 Configure the RF Amplifier in the same configuration as the one it is intended to
replace in the field (i.e., same attenuator pads, forward/reverse EQ values, and
same AGC / Thermal setting).
same AGC / Thermal setting).
13 All S parameters on each port in the forward and reverse band should be verified
using a network analyzer.
CAUTION:
Modifying an amplifier's split characteristics will impact the available
channel lineup downstream from the upgraded amplifier.
channel lineup downstream from the upgraded amplifier.
Note: Properly dispose of all parts you remove to protect the environment and to
avoid their re-use, which could impact network performance.
avoid their re-use, which could impact network performance.
Installing the Amplifier Module in the Housing
1 Insert the upgraded RF amplifier module into the housing.
2 Secure the amplifier module to the housing by tightening the four module
1 Insert the upgraded RF amplifier module into the housing.
2 Secure the amplifier module to the housing by tightening the four module
retainer screws with a screwdriver from 6 in-lb to 9 in-lb (0.7 Nm to 1.0 Nm).
3 Inspect the housing gasket and all mating surfaces. Wipe off any excess dirt and
debris.
4 Close the housing and finger-tighten all closure bolts.
5 Use a torque wrench with a ½-inch socket to tighten each closure bolt from 5 ft-lb
5 Use a torque wrench with a ½-inch socket to tighten each closure bolt from 5 ft-lb
to 12 ft-lb (6.8 Nm to 16.3 Nm) each.