Fuse Replacement Procedure for the Cisco MeetingPlace 8106
OL-7808-01
  How To Replace Fuses
Figure 1
Back of Cisco MeetingPlace 8106 with the Fuse Holder Module
Step 2
There is a notch at the bottom of the fuse panel where you can insert a flat-head screwdriver or some 
other flat object. Pry open the fuse panel. It opens upward from the bottom.
Step 3
Pull out the red fuse holder. The red fuse holder has a fuse on each side.
Step 4
Remove the old fuses by gently pulling them out.
Installing Fuses
Warning
Do not touch any of the exposed leads, terminals, or components of the Cisco MeetingPlace 8106 
unless you have powered it off and removed the power cord. Hazardous voltages, capable of causing 
death, are present in this product. Removing or touching the fuse module before disconnecting the 
power cord will expose you to these hazardous voltages.
Step 1
Pop the new fuses, one on each side, into the red fuse holder. The Cisco MeetingPlace 8106 uses two 
4-amp, 250-volt, AGC-type fuses that have a 0.25 inch diameter and are 1.25 inches long.
Step 2
Slide the red fuse holder back into the fuse holder module.
Step 3
Snap shut the cover of the fuse panel.
92718
1
2
3
1
Fuse panel notch
3
Fuse holder module
2
Fuse holder