Cisco Cisco Packet Data Gateway (PDG) Installation Guide

Page of 317
Cabling the Power Filter Units   
▀  Connecting the PFU to the Power Source 
 
 
▄  ASR 5000 Installation Guide 
152 
   
Step 6 
Reinstall the plastic terminal cover. 
Caution:
  To avoid the risk of potential damage to the system, never operate the chassis without the plastic 
terminal cover installed. Make sure that the power and return lugs do not protrude past the edge of the plastic terminal 
covers. Any portion of the lug that is exposed must be covered with heat shrink tubing. 
Step 7 
Repeat step 1 through step 6 for the PFU installed in the bay labeled Power Filter Unit 2. 
Step 8 
Proceed to the next chapter for information and instructions on applying power to the chassis and verifying that the 
installation was successful.