Flash status word reference table
The flash status word is used in diagnosing NTP server synchronization issues.
It is displayed by the ntpq program rv command. It comprises a number of bits, coded in hexadecimal as 
follows:
Code
Tag
Message
Description
0001
TEST1
pkt_dup
duplicate packet
0002
TEST2
pkt_bogus
bogus packet
0004
TEST3
pkt_unsync
server not synchronized
0008
TEST4
pkt_denied
access denied
0010
TEST5
pkt_auth
authentication failure
0020
TEST6
pkt_stratum
invalid leap or stratum
0040
TEST7
pkt_header
header distance exceeded
0080
TEST8
pkt_autokey
Autokey sequence error
0100
TEST9
pkt_crypto
Autokey protocol error
0200
TEST10
peer_stratum
invalid header or stratum
0400
TEST11
peer_dist
distance threshold exceeded
0800
TEST12
peer_loop
synchronization loop
1000
TEST13
peer_unreach
unreachable or nonselect