Introduction
This document explains software error 364. This error can occur on the IPX, IGX, or BPX switches.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Software Error 364
Software error (swerr) 364 is logged when a connection is routed off a trunk and the connection load units are
removed from the trunk. This results in a negative value. The error is the result of an incorrect loading view
on the node that logged it.
removed from the trunk. This results in a negative value. The error is the result of an incorrect loading view
on the node that logged it.
The swerr Data field indicates the node and trunk with which it does not agree, as this example shows:
No. Type Number Data(Hex) PC(Hex) PROC SwRev Date Time
1. Error 364 080E0001 3004D17A TRNS 9.3.45 08/18/03 21:51:06
01 = number of conns.
00 = local domain (01 = GTWY_DOMAIN)
0E = trunk number
08 = node number
Issue the dspload command for the trunk on both the node that logged the error and the node in conflict to
show the load inconsistency.