Cisco Cisco Email Security Appliance C370D Release Notes

Page of 24
 
17
Release Notes for Cisco IronPort AsyncOS 7.5.2 for Email
OL-25139-02
  Fixed Issues in Release 7.5
68527
Fixed: Misleading Message When Trying to Run DLP Assessment Wizard in 
Cluster Mode.
Previously, AsyncOS displayed an incorrect error message when you attempted to run 
DLP Assessment Wizard a clustered environment, stating that the wizard must be run 
from the “login host” level. This error message has been corrected. The message now 
correctly states that the appliance must be removed from the cluster to run the DLP 
Assessment Wizard.
29829
Fixed: updateconfig Command Does Not Allow User to Specify Interface for 
Certain Service Updates.
Previously, you could not correctly apply which of IP interfaces assigned to the same 
physical network interface to use when connecting to the update server. That was a 
reason of failed updates/upgrades. This issue has been resolved. Now, when you run 
the updateconfig -> setup command and choose which particular IP interface connects 
to the update server the selected IP interface is applied properly and updates/upgrades 
are always completed successfully.
71406
Fixed: Error Occurs When Using the Default Client or Server IP Address for the 
packetcapture Predefined Filter.
Previously, configuring the client and server IPs addresses for the packetcapture 
feature’s predefined filter could result in a configuration error. The error occurred if 
an IP address was specified for one of the client or server IP addresses and the default 
address was used for the other. For example, if your configuration specified an IP 
address for the client IP but used the default IP address for the server IP. In these cases, 
AsyncOS saved a comma-separated string value for the packetcapture configuration 
instead of a list, which resulted in a error message after saving. 
This issue has been resolved. When configuring packetcapture in AsyncOS 7.5, the 
system uses a comma-separated string for the client and server IP addresses. However, 
AsyncOS 7.5 cannot fix a broken, existing XML configuration as there is no single 
way to fix the broken packetcapture settings. These settings may let the loadconfig fail 
or result into loading inappropriate settings for client or server IP addresses.  The 
packetcapture will fail to start with these settings and user will have to manually 
correct settings using 
packetcapture -> setup
 command.
Table 4
Resolved Issues in Version 7.5 (continued)
Defect ID
Description