Cisco Cisco ASA 5512-X Adaptive Security Appliance Release Notes
7
Release Notes for the Cisco ASA 5500 Series, Version 8.2(x)
System Requirements
Viewing Flash Memory
You can check the size of internal flash and the amount of free flash memory on the ASA by doing the
following:
following:
•
ASDM—Choose Tools > File Management. The amounts of total and available flash memory
appear on the bottom left in the pane.
appear on the bottom left in the pane.
•
CLI—In privileged EXEC mode, enter the dir command. The amounts of total and available flash
memory appear on the bottom of the output.
memory appear on the bottom of the output.
For example:
hostname # dir
Directory of disk0:/
43 -rwx 14358528 08:46:02 Feb 19 2007 cdisk.bin
136 -rwx 12456368 10:25:08 Feb 20 2007 asdmfile
58 -rwx 6342320 08:44:54 Feb 19 2007 asdm-600110.bin
61 -rwx 416354 11:50:58 Feb 07 2007 sslclient-win-1.1.3.173.pkg
62 -rwx 23689 08:48:04 Jan 30 2007 asa1_backup.cfg
66 -rwx 425 11:45:52 Dec 05 2006 anyconnect
70 -rwx 774 05:57:48 Nov 22 2006 cvcprofile.xml
71 -rwx 338 15:48:40 Nov 29 2006 tmpAsdmCustomization430406526
72 -rwx 32 09:35:40 Dec 08 2006 LOCAL-CA-SERVER.ser
73 -rwx 2205678 07:19:22 Jan 05 2007 vpn-win32-Release-2.0.0156-k9.pkg
74 -rwx 3380111 11:39:36 Feb 12 2007 securedesktop_asa_3_2_0_56.pkg
62881792 bytes total (3854336 bytes free)
hostname #
DRAM, Flash Memory, and Failover
In a failover configuration, the two units must have the same hardware configuration, must be the same
model, must have the same number and types of interfaces, must have the same feature licenses, and must
have the same amount of DRAM. You do not have to have the same amount of flash memory. For more
information, see the failover chapters in Cisco ASA 5500 Series Configuration Guide using the CLI.
model, must have the same number and types of interfaces, must have the same feature licenses, and must
have the same amount of DRAM. You do not have to have the same amount of flash memory. For more
information, see the failover chapters in Cisco ASA 5500 Series Configuration Guide using the CLI.
Note
If you use two units with different flash memory sizes, make sure that the unit with the smaller flash
memory has enough space for the software images and configuration files.
memory has enough space for the software images and configuration files.
Table 3
CompactFlash Upgrades
CompactFlash Upgrades Available
Product Identification Number
ASA 5500 Series CompactFlash, 256 MB
ASA5500-CF-256MB=
ASA 5500 Series CompactFlash, 512 MB
ASA5500-CF-512MB=