Cisco Prisma II 1310 nm HDTx Transmitters Installation Guide

Page of 125
5-4 
Maintenance and Troubleshooting 
78-4010846-01 Rev D 
Troubleshooting Alarm Conditions 
Alarm Conditions
 
If the red ALARM indicator is illuminated or is blinking, check the ICIM, LCI, or 
TNCS to determine the cause of the alarm. For help, refer to the chart below. 
 
Alarm 
Parameter 
Possible Causes 
Possible Solutions 
LasBias 
Laser Current  
Internal problem 
Contact Cisco 
Services for help. 
InPwr 
Optical Input  
Dirty or loose 
connector, or  Low 
input 
Check input 
source. 
OutPwr 
Optical Output 
Low input, 
Internal problem 
Check input. 
Contact Cisco 
Services for help. 
 
 
Module disabled 
Enable Module. 
LasTemp 
Laser Temperature  Internal problem, 
Fan Tray failure, 
Ambient 
Temperature, or 
chassis air filter 
requires changing 
Contact Cisco 
Services for help. 
IntPs 
Input Power 
Supply 
Internal problem 
Contact Cisco 
Services for help.