Cisco Model GS7000 4-Port Node 1 GHz with 55 70 Split Installation Guide

Page of 254
 
 
Reconfiguring Forward Signal Routing 
 
107 
 
 
 
1x4 Redundant Forward Configuration Modules with Forward RF 
Injection 
A primary receiver (RCVR 1) and a redundant receiver (RCVR 2) feed all RF output 
ports. The FLI Module routes an RF signal from an external source to the Forward 
Configuration Module which is then coupled with the input from RCVR 1/2. 
The Status Monitor/Local Control Module automatically switches from primary 
receiver to redundant receiver when it senses a loss of optical input to the primary 
receiver. Once optical input is restored, the system automatically switches back to 
the primary receiver. 
Install the primary receiver in RCVR 1 and the redundant receiver in RCVR 2. Install 
the FLI module in the RCVR 4 position. When using this module remove the 0.5dB 
forward interstage attenuator pads and replace with 0dB attenuator pads. 
 
4-way forward segmentable node 
 
The following diagram illustrates forward path signal flow in this configuration 
module.