Cisco Model GS7000 4-Port Node 1 GHz with 55 70 Split Installation Guide

Page of 254
 
 
Power Distribution 
 
23 
 
Power Distribution 
Introduction 
The 1.2 GHz GS7000 Node is powered by one or two power supplies. 
 
Power Distribution 
1.2 GHz GS7000 Node power distribution functions are described below. 
Stage 
Description 
45 to 90 V AC is applied to one or two power supply modules in the 1.2 GHz 
GS7000 Node. 
The power supply module(s) convert(s) the AC input to +24.5, +8.5, -6.0, and 
+5.5 V DC. 
The +24.5, +8.5, -6.0, and +5.5 V DC lines are routed to 1.2 GHz GS7000 Node 
internal modules. 
If two power supplies are installed and both are active, the load is shared 
equally between them. 
An AC segmentable shunt is available to separate the AC connection to ports 
1-3 from that of ports 4-6. This allows the node to be configured where one 
power supply is powered from ports 1-3 and a second power supply is powered 
from ports 4-6.