B.2 FST Connection 
 
This section describes connection between the main unit and the FST. 
   
APP0202010 
B.2.1 FST Setup and Connection   
 
Use the following instructions for setting the FST and connecting between the FST and the MMB. 
 
(1) Connect a LAN straight cable between the FST LAN port and the MMB LOCAL port on the   
MMB.    See Figure B.2.1, “MMB external interface”. 
ANNT)Do not connect the cables to the MMB User ports. 
 
Figure B.2.1 MMB external interface 
 
 
(2) Start the FST. 
(3) Start the terminal software, and select the serial port connected to the FST. 
(4) Set up the terminal software. See Table B.2.1, "Terminal software settings." 
Table B.2.1 Terminal software settings 
Setting item 
Value 
Transfer rate (bps) 
19200 
Data bits 
Parity 
None 
Stop bit 
Flow control 
None 
Emulation 
VT100 
Terminal size 
80 x 24 
 
(5) Configure FST with the "IP Address" and "Subnet mask". 
(6) Specify the Web browser security settings. 
   Set for the file download dialog box not to be blocked.   
ANNT)Web browser security settings may be ignored. 
 
(7) When OS for FST is Windows Vista or newer version, disable UAP (User Account Protection) or   
   UAC (User Account Control). Check each Windows OS manual and etc.... for more details. 
 
 
 