2.3 
Connection Specifications of Input Power  
This section describes the connection specifications of Input power of the base cabinet of Cisco C880 Server. 
2.3.1  Input Power Connection Specifications (Base Cabinet) 
Following table shows the input power connection specifications of the main unit. 
TABLE 2.1 Power Cable Specifications (Base Cabinet) 
Destination 
Plug format 
Remarks 
100 V 
Parallel 2-pole plug 
with earthing-contact 
“NEMA standard 5-
15P” 
Connection at wall-mount power distribution 
Recipient power distribution 
format 
 
Power distribution “NEMA 
standard  5-
15R” for parallel 
2-pole plug with earthing - 
contact (125V 15A)  
200 V 
IEC60320-C20 type 
Connection at power distribution box 
Recipient outlet format 
 
IEC60320-C19type 
Remarks 
Power cable supplied with the device and power cord supplied with the option part, are used for the 
power cable which is connected to the device. However, the supplied power cable is not used for the 
other products. 
Power distribution box which is suitable to recipient power distribution format is used 
2.3.2  Power Distribution Box and Distribution Panel 
Following table shows the power supply cable specifications of power distribution box and distribution panel. 
TABLE 2.2 Power Supply Cable Specifications of Power Distribution Box and Distribution Panel 
Destination 
Plug format 
Remarks 
200V for countries 
other than Japan 
NEMAL6-30P 
Recipient power 
distribution format  
 
NEMA L6-30R (30A-
220V) 
200V for Brazil 
IEC60309-32A 
Recipient power 
distribution format  
 
IEC60309-32A (32A-
250V) 
Remarks 
Power cable supplied with the device and power cord supplied with the option part, are not used for the 
power cable which is connected to the device. However, the supplied power cable is not used for the other 