Cisco Cisco C880 M4 Server Installation Guide

Page of 48
5.Hard Disk Drives 
                                                                                                                                                                                21 
 
 
 
5.2.  Removing/Installing Hard Disk Drive/Blank Insert 
 
CAUTION! 
Do not remove a hard disk drive from an operating array  if  you  are  not  sure  that  it  belongs  to  a 
faultless and fault tolerance RAID  configuration (RAID level 1, 5, 6, 10, 50 or 60), otherwise data will 
be lost. 
The hard disk drives must all be marked clearly so that they can be put  back into the original bays 
after an upgrade. If this is not taken into  account, existing data can be destroyed. 
To avoid temperature rise, replacing a hard disk should be finished within  5 minutes if the storage 
subsystem is operating. 
The hard disk drives which can be ordered for the storage subsystem are delivered pre-installed in frames. 
Removing a hard disk drive  from the frame may only be done in authorized repair centers. 
 
 
Figure 12: Hard disk drive in frame