9.1. Problem Solutions and Tips
The following sections describe irregularities which can be observed on the storage subsystem in case of
faults. Their possible causes are named and there are instructions for fault clearing.
Power Supply Status LED (Front)
9.1.1.
If the power supply status LED is green the device is switched on and the power supply and at least one
power supply unit are OK.
9.1.1.1. Power supply status LED remains dark
Power cable not connected correctly
Ensure that the power cable on the storage subsystem and the safety socket
are connected correctly.
Power supply unit defective
Check the LEDs of the power supply units.
If the
„Fault“ LED (amber LED) on a power supply unit is on, the power supply unit is defective.
Replace the defective power supply unit.
For more information refer to
section
Identification Status LED
9.1.2.
9.1.2.1. Identification status LED is on
ServerView switched on this LED for identification. No error.