Busy Message not sent when Port Limit is Reached
The MCU returns a TRYING message once the port limit is reached instead of a 486 busy message. This is only an 
issue when MCU is directly trunked from Cisco Unified Communications Manager.  We recommend deploying the MCU
(s) behind Cisco TelePresence Conductor to avoid this.
The MCU does not Support Sender-Side Flow Control
The MCU does not support sender-side media flow control. This can create problems when calls are made over low 
bandwidth pipes to endpoints that do not support receive-side flow control. In such calls, flow control is not possible 
for the media from the MCU to the endpoint. To assist in this situation low bandwidth can be set on the endpoint.
Unable to Add a VNC User on Windows 7 for MCU
It is not possible to add a VNC user to an MCU conference if the VNC user is running Windows 7 on their desktop. 
This is an issue on the Microsoft side - the connection will attempt to call out but fail. In the MCU logs the following 
error message will appear:
 Connect failed with errno 60.
 The workaround is for the VNC user to upgrade to 
Windows 7 SP1 and apply the necessary updates.  (Issue identifier CSCun87357) 
Slot 10 of the Cisco TelePresence MSE 8000 Chassis does not Support Clustering
Slot 10 of the Cisco TelePresence MSE 8000 chassis does not support clustering in this MCU software release. 
However, slot 10 in the same chassis as a cluster can be used for a standalone blade of any type.   (Issue identifier 
CSCtr53874) 
MCU Times Out Outbound SIP Call After 64 seconds  
If an outbound SIP call from an MCU takes longer than 64 seconds to connect, the MCU may time-out the call before 
call set-up is complete.  (Issue identifier CSCum70556) . To work around this:
 
Reduce the call setup time by reconfiguring other nodes in the call path, or 
 
Use H.323, which has a longer timeout. (The Cisco TelePresence VCS can interwork between H.323 and SIP.)
Windows Media Player Streaming Only Works Over HTTP
Windows Media Player (WMP) streaming will work if the protocol is set to HTTP or Auto-negotiate, but there may be a 
delay in connection for auto-negotiate. MMS streaming will fail, and has also been removed from WMP 11 and 
onwards.