Fluke TS100 26500610 Leaflet

Product codes
26500610
Page of 2
N E T W O R K
S U P E R
V I S I O N
Fluke Networks
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries  
worldwide. To find your local office contact details,  
go to 
www.flukenetworks.com/contact
.
©
2006 Fluke Corporation. All rights reserved. 
Printed in U.S.A. 2/2006 2631486 D-ENG-N Rev A
Model
Description
26500090
TS90 cable fault finder with BNC to alligator clips
26500000
TS100 cable fault finder with BNC to alligator clips
26500500
TS100 with BNC to banana to Angled Bed-of-Nails clips
26500610
TS100 metric cable fault finder with BNC to alligator clips
26501100
TS100/TS90 linecord, BNC to alligator clip
26501200
TS100/TS90 linecord, BNC to F(MALE)
26501300
TS100/TS90 linecord, BNC to F(FEMALE)
26501600
TS100/TS90 linecord, banana
26501700
TS100/TS90 linecord, BNC to banana to Angled Bed-of-Nails clips
26501160
TS100/TS90 pouch with belt clip
Ordering Information
Power
4 AA alkaline batteries provide 50 hours “on” 
time. (Approx. 1 year, normal use). 5 minute 
auto-off if unit is not connected; 1 hour auto-off 
when connected. No damage if batteries are 
installed backwards.
Input protection
250 V RMS AC, Continuous or Intermittent.
Moisture
If exposed to water, TS 90 and TS100 will suffer 
no damage. See moisture notes in Notices section 
of manual.
Impedance range
Auto-compensation within 25 to 330 ohms. 
Cables with an impedance outside this range may 
produce erratic or incorrect readings.
Maximum length
The unit will display “-LL-” if the cable is too 
long to be correctly measured. 
Maximum cable testing length
2,500 feet for the TS90, 3000 feet for the TS100 
(can test longer on certain cables)
Minimum length
No minimum length. Minimum non-zero reading 
is 1 foot.
High voltage detection
AC voltage > 5 to 15 Volts RMS will trigger High 
Voltage Warning.
Measurement rate
Maximum of 4 complete measurements/second, 
decreasing to 2 seconds per measurement. Based 
on cable size and uniformity.
Measurement technology
Time Domain Reflectometry (TDR) with 50 ohm 
drive impedance, 6 V maximum pulse height. 
(Patents Pending).
Tone injection
Approximately 1 kHz at an amplitude of 80% 
battery voltage. Variable frequency and cadence. 
Tone changes when cable condition changes to 
“normal-open” from any other condition.
Cable type
Virtually all two or more conductor cables
Temperature
0º to 55º C operating; 0º to 70º C storage
Dimensions
7.4” tall x 1.5” thick x 2.75” wide
Specifications