Cisco Cisco Prisma II ICIM Installation Guide

Page of 106
3-16 
Operation Using the ICIM 
78-713378-01 Rev C 
Configuring the Reverse Receiver Using the ICIM 
Configurable Parameters  
Configurable parameters for the Prisma II Reverse Receiver are listed below. 
 
Continued on next page 
 
Control  
Function 
Values 
Default 
Mute1, 
Mute2 
Force Mute.  Muting of the RF signal and 
removal of power to the amplifier only if the 
Enable control is on for this particular side.  
ON or OFF
 
OFF 
Enable1, 
Enable2 
Enables or disables unit operation, i.e., 
muting enabled and no alarm capability 
ON or OFF
 
ON 
Alarm1, 
Alarm2 
Force Alarm.  Alarm relay is manually 
overridden only if the Enable control is On. 
This sets a particular side to alarm as if there 
was an internal alarm, i.e., Alarm output 
high, muting on as per Force Mute above 
ON or OFF
 
OFF 
Master1, 
Master2 
Configures the module as master or slave. If 
set to Master, the unit is controlled only by 
the Enable control above. If set to Slave, the 
unit is controlled by a combination of the 
Enable control and the external input 
CNT_IN_1 or CNT_IN_2. 
ON or OFF
 
ON 
Atten1 
Atten2 
Sets the attenuation level of the output RF 
signal. 
Decimal number 
between 0 and 20 
dB, increments of 
0.5 dB 
0 dB 
NomPwr1, 
NomPwr2 
The nominal input optical power level, in 
dBm. 
Decimal number 
between –20 and 
0 dBm, 
increments of 0.5 
dBm 
0 dB