Cisco Cisco Prisma II ICIM Installation Guide

Page of 106
3-22 
Operation Using the ICIM 
78-713378-01 Rev C 
Checking Reverse Receiver Alarms Using the ICIM, 
Continued
 
Setting User Alarm Thresholds 
User alarms have adjustable thresholds.  To change a user alarm threshold from the 
factory default, follow the steps below. 
1. 
At the MODULE menu, press the 
STAT
 key.  The STATUS menu is displayed 
on the ICIM. 
2. 
Press the 
SEL
 key.  The alarm thresholds previously set are displayed. If the 
label n/a is displayed, you cannot configure that alarm threshold.  Press the 
 
 key to highlight the next parameter’s alarm threshold. 
3. 
When the threshold that you wish to set is highlighted, press the 
ENTER
 key.   
4. 
Press the 
 
 key or the 
 key to adjust the alarm threshold.   
5. 
Press the 
ENTER
 key to save the changes.  Data Saved is displayed. 
6. 
When finished, press the 
MAIN
 key to return to the MAIN menu. 
Reverse Receiver Alarm Threshold Menus 
Some typical alarm threshold menus are shown below. 
 
 
 
 
 
 
 
 
 
 
 
    S T A T U S     
-  -  -  -  -  -  -  -  -  - 
S h e  l  f        0   
S  l  o  t          6   
-  -  -  -  -  -  -  -  -  - 
  R e v e  r s  e     
      D a  t  a       
  R e c e  i  v e  r   
-  -  -  -  -  -  -  -  -  - 
    I  n P w r  1     
M a  j  H 3  .  2 0 0   
M i  n H 2  .  0 0 0   
M i  n L  -  4  .  0 0 0 
M a  j  L  -  2 0  .  0 0 
                   
 
 
    S T A T U S     
-  -  -  -  -  -  -  -  -  - 
S h e  l  f        0   
S  l  o  t          6   
-  -  -  -  -  -  -  -  -  - 
  R e v e  r s  e     
      D a  t  a       
  R e c e  i  v e  r   
-  -  -  -  -  -  -  -  -  - 
I  n P w r  1 M x     
M a  j  H 3  .  2 0 0   
M i  n H 3  .  2 0 0   
M i  n L  -  1 0 0  .  0 
M a  j  L  -  1 0 0  .  0 
                   
 
 
    S T A T U S     
-  -  -  -  -  -  -  -  -  - 
S h e  l  f        0   
S  l  o  t          6   
-  -  -  -  -  -  -  -  -  - 
  R e v e  r s  e     
      D a  t  a       
  R e c e  i  v e  r   
-  -  -  -  -  -  -  -  -  - 
    I  n P w r  2     
M a  j  H 3  .  2 0 0   
M i  n H 2  .  0 0 0   
M i  n L  -  4  .  0 0 0 
M a  j  L  -  2 0  .  0 0 
                   
 
 
    S T A T U S     
-  -  -  -  -  -  -  -  -  - 
S h e  l  f        0   
S  l  o  t          6   
-  -  -  -  -  -  -  -  -  - 
  R e v e  r s  e     
      D a  t  a       
  R e c e  i  v e  r   
-  -  -  -  -  -  -  -  -  - 
I  n P w r  2 M x     
M a  j  H 3  .  2 0 0   
M i  n H 3  .  2 0 0   
M i  n L  -  1 0 0  .  0 
M a  j  L  -  1 0 0  .  0