Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 178
 
Appendix A 
Module Parameter Descriptions 
144 
 
Parameter 
Name (LCI) 
ICIM 
Abbreviation 
Description 
Values 
Default 
Rx Mode
1
 
RxMode
1
 
Sets the receiver operating mode 
2.5GHz or 5GHz. 
Note: Changing the Rx Mode forces 
the FPGA to be reprogrammed. 
This takes about 10 seconds, so user 
may notice a delay before the 
change takes effect. 
0: 5GHz 
1: 2.5GHz 
 
5GHz 
RF Ports 
RxPorts 
Sets whether the RF output is gated 
to both connectors or just the top 
connector. Refer to block diagrams 
in page 36. 

Node Select 
NodeSel 
Selects the node to be monitored 
(Node 1 to Node 4) 
1: Node 1 
2: Node 2 
3: Node 3 
4: Node 4 
Note: All parameters below this point in the table relate to the attached node and are monitor-only. 
Path 1 
Redundancy 
Path 2 
Redundancy 
NdPth1Rd 
NdPth2Rd 
Selects the redundancy mode for 
the node connected to the Rx1 or 
Rx2 optical path: Primary, 
Redundant, or Failure. 
0: N/A 
1: Primary 
2: Redundant 
3: Failure 
 
Node 
Temperature 
NodeTemp 
Node temperature in degrees C 
degC 
 
PS 1 Status 
PS 2 Status 
NdPS1Flt 
NdPS2Flt 
Indication that one or more PS1 or 
PS2 voltages are out of spec. 
0: OK 
1: Fault 
 
AC Status 
NdACFlt 
Indicates that the AC power input 
is either too high or too low. 
0: OK 
1: Fault 
 
PS 1 24V 
PS 2 24V 
NdPS1+24 
NdPS2+24 
Indicates the actual output voltage 
of the PS1 or PS2 +24 VDC power 
supply. 
N/A 
Tx 1 Power Level 
Tx 2 Power Level 
Tx 3 Power Level 
Tx 4 Power Level 
NdTx1Pwr 
NdTx2Pwr 
NdTx3Pwr 
NdTx4Pwr 
Indicates the output power of Tx1, 
Tx2, Tx3, or Tx4. 
dBm