Chapter 3        Operation using ICIM 
 
 
 
76 
 
fan tray is not installed in the Prisma II Chassis, the ICIM will not communicate 
with any of the modules in that chassis. 
 
All chassis connected in a daisy-chain must be powered and have a fan tray 
installed. A chassis that is connected but is either not powered, or does not have 
a fan tray installed will cause faulty operation of the ICIM. 
 
All chassis connected in this daisy-chain must have a unique chassis 
identification (ID) number. 
 
The last chassis in the daisy-chain must have a terminator installed in the ICIM 
OUT
 connector. Otherwise, faulty communication with the ICIM may occur. 
 
ICIM Block Diagram 
A block diagram representing the ICIM2 or ICIM2-XD is shown below. 
 Prisma II Standard / XD Chassis
ICIM2 / ICIM2-XD
Module
Microprocessor
Ethernet
CLI
Hardware 
Interface
Hardware 
Interface
Hardware 
Interface
RS-232
RJ-45
ICIM 
In
Backplane /
Midplane
Bus 
Connection
DB-9
DB-9
ICIM 
Out
Configuration & Monitoring Bus
TP514
LCD
Keypad
(Absent from ICIM2-XD)