Cisco Headend System Release 2.7 Installation Guide
Appendix E
Perform a DNCS Upgrade in a Disaster Recovery Enabled Network
174
4023737 Rev C
18 If the Full Sync completes successfully, you will want to check the Active MC for
the emulated QAM configurations for both the bge3 sub-interfaces and the
unique instances of the QAM Emulator as follows:
Open a terminal/XTERM window and enter:
NUMBER INTERFACES = ifconfig -a | grep bge3 | wc -l
NUMBER INSTANCES = ps -ef | grep Qam | wc -l
Note: The NUMBER INTERFACES and NUMBER INSTANCES should be equal
to each other.
unique instances of the QAM Emulator as follows:
Open a terminal/XTERM window and enter:
NUMBER INTERFACES = ifconfig -a | grep bge3 | wc -l
NUMBER INSTANCES = ps -ef | grep Qam | wc -l
Note: The NUMBER INTERFACES and NUMBER INSTANCES should be equal
to each other.