Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 12
 
 
 
Model GS7000 GainMaker Node 
1x/2x-3x-4x Local Control Module to 
Status Monitor Upgrade Instructions 
Introduction 
The Model GS7000 GainMaker
®
 Scaleable 4-Port Node can be optionally equipped 
with a either a Status Monitor (SM) or a Local Control Module (LCM).  For 
complete instructions on installing and operating the SM/LCM refer to Model 
GS7000 GainMaker Node 1x/2x-3x-4x Status Monitor/Local Control Module Installation 
and Operation Guide, part number 4024769. 
A Local Control Module can be field upgraded to a Status Monitor through the 
addition of a transponder core module.  The transponder core module plugs 
directly onto the Local Control Module’s main PWB.  The mechanical housing for 
the Status Monitor and the Local Control Module are the same. 
This document explains the LCM to SM field upgrade procedure for a 4-way 
LCM, part number 4024775. 
The Status Monitor Upgrade Kit, part number 4024777, contains the following 
items: 
 
Transponder core module (1) 
 
Plastic stand-offs (2) 
 
Upgrade instructions (1) 
IMPORTANT:  This kit can only be used to upgrade a 1x/2x-3x-4x LCM, not to 
upgrade an earlier legacy LCM for a 2-way GS7000 node.  Make sure the LCM 
you are upgrading is a 1x/2x-3x-4x LCM, part number 4024775, which has two 
round cut-outs on the front panel, one labeled SM and one labeled LCM, as shown 
in Local Control Module Description (on page 2).  A legacy 2-way LCM, part 
number 4011932, only has one round cut-out on the front panel labeled Local 
Control Port.  If you need to upgrade a legacy 2-way LCM to a SM, use upgrade 
kit part number 4011933 instead.