Cisco Cisco TelePresence MCU 4510 Release Notes

Page of 28
Document revision history
Cisco TelePresence MCU 4.4(3.57) Maintenance Release Notes
Page 26 of 28
 1.  Ensure that an appropriate HTTPS trust store has been installed on the MCU (
Network > SSL 
certificates
).
 2.  Go to 
Network > Services
 and enable both  HTTP and HTTPS.
 3.  Go to 
Settings > Security
 and disable Redirect HTTP requests to HTTPS. This ensures that you can 
fall back to HTTP if problems occur.
 4.  Go to 
Network > SSL certificates
.
 a.  Scroll to the 
Online certificate status protocol (OCSP)
 section. 
 b.  Set Certificate to check to HTTPS client certificates.
 c.  Enter the URL of the external OCSP server and set any options you require.
 d.  Click Apply changes.
 5.  Now test that you are able to log in to the MCU over an HTTPS connection. Only proceed to the next step 
if you can successfully log in. 
 6.  Do one of the following, as appropriate for your configuration:
 
Go to 
Network > Services
 and disable HTTP.
 
Go to 
Settings > Security
 and enable Redirect HTTP requests to HTTPS.
Requiring certificate-only login (all connections)
To transition from password-based authentication to required certificate-based authentication for all 
connection types, do the following:
 1.  Ensure that an appropriate HTTPS trust store is installed on the MCU (
Network > SSL certificates
) and 
that the web browser(s) to be used to access the MCU are configured with a valid client certificate.  
 2.  Go to 
Network > Services
 and enable both  HTTP and HTTPS.
 3.  Go to 
Settings > Security
 and disable Redirect HTTP requests to HTTPS (uncheck the check box). 
This ensures that you can fall back to HTTP if problems occur.
 4.  Go to 
Network > SSL certificates
:
 a.  Scroll to the 
HTTPS trust store
 section. 
 b.  Set Client certificate security to Certificate-based authentication allowed
Do NOT set Client certificate security to Certificate-based authentication required yet. 
 c.  Click Apply changes.
 5.  Now test that you are able to log in to the MCU over an HTTPS connection using a certificate. Only 
proceed to the next step if you can successfully log in with a certificate. 
 6.  Assuming the previous step succeeded, go to the Client certificate security option again and this time 
set it to Certificate-based authentication required
 7.  Click Apply changes and confirm at the prompt. 
It is now not possible to log in over HTTP. To log in over HTTPS requires a valid client certificate signed 
by a certificate authority, which matches the HTTPS trust store on the MCU.
 8.  Do one of the following, as appropriate for your configuration:
 
Go to 
Network > Services
 and disable HTTP.
 
Go to 
Settings > Security
 and enable Redirect HTTP requests to HTTPS.
Document revision history
Date
Revision
Description
December 2012
16
Release version.