Cisco Cisco TelePresence MCU 4510 Maintenance Manual

Page of 252
Displaying hardware health status 
Cisco TelePresence MCU Version 4.2 Printable online help 
Page 212 of 252 
 
 
Displaying hardware health status  
The Health status page (Status > Health) displays information about the hardware components of 
the MCU. 
NOTE: The Worst status seen conditions are those since the last time the MCU was restarted.  
To reset these values, click Clear. Refer to the table below for assistance in interpreting the 
information displayed. 
  
Field 
Field description 
Usage tips  
Fans (on 
MCU 4200 & 
4500 Series) 
Voltages 
RTC battery 
Displays two possible states:  
 
OK  
 
Out of spec 
States indicate both Current status and 
Worst status seen conditions.  
The states indicate the following: 
 
OK – component is functioning 
properly  
 
Out of spec – Check with your support 
provider; component might require 
service 
If the Worst status seen column displays 
Out of spec, but Current status is OK
monitor the status regularly to verify that it 
was only a temporary condition. 
Temperature 
Displays three possible states:  
 
OK  
 
Out of spec 
 
Critical 
States indicate both Current status and 
Worst status seen conditions. 
The states indicate the following: 
 
OK – temperature of the MCU is within 
the appropriate range  
 
Out of spec – Check the ambient 
temperature (should be less than 34 
degrees Celsius) and verify that the air 
vents are not blocked  
 
Critical – temperature of MCU is too 
high. An error also appears in the 
event log indicating that the system 
will shutdown in 60 seconds if the 
condition persists  
If the Worst status seen column displays 
Out of spec, but Current status is OK 
monitor the status regularly to verify that it 
was only a temporary condition.