Cisco Cisco TelePresence MCU 4510 Maintenance Manual
Logging using syslog
Cisco TelePresence MCU Version 4.2 Printable online help
Page 230 of 252
Using syslog
The events that are forwarded to the syslog receiver hosts are controlled by the event log capture
filter.
filter.
To define a syslog server, simply enter its IP address and then click Update syslog settings. The
number of packets sent to each configured host is displayed next to its IP address.
number of packets sent to each configured host is displayed next to its IP address.
Note: Each event will have a severity indicator as follows:
0 - Emergency: system is unusable (unused by the MCU)
1 - Alert: action must be taken immediately (unused by the MCU)
2 - Critical: critical conditions (unused by the MCU)
3 - Error: error conditions (used by MCU
error
events)
4 - Warning: warning conditions (used by MCU
warning
events)
5 - Notice: normal but significant condition (used by MCU
info
events)
6 - Informational: informational messages (used by MCU
trace
events)
7 - Debug: debug-level messages (used by MCU
detailed trace
events)