Cisco Cisco UCS C24 M3 Rack Server White Paper

Page of 51
24   © 2016 Cisco and/or its affiliates. All rights reserved.
Note: Disable the HA and DRS features while configuring the VMware cluster. After the SvSAN mirrored storage and workload is 
configured, you can enable the HA and DRS features and configure the VMware cluster according to your requirements. 
In the Cisco UCS C-Series configuration, NSH is installed on a vCenter Server that is running on a separate ESXi host. This 
setup helps prevent a split-brain scenario in the event of a network fault.
1.  Log in to the vCenter Server.
2. Select 
Run as Administrator and run the setup.exe file provided in the downloaded zip file.
3. Click 
Next. The end-user license agreement (EULA) opens.
Note: There are different versions of the EULA for the USA and for the rest of the world. Scroll down to find the appropriate 
agreement.
4.  To accept the agreement, select the box. Then click 
Next.
5. Click 
Custom.
6.  Verify that the 
StorMagic Neutral Storage Service and StorMagic vCenter Integration Services options are selected 
(Figure 28). The plug-in components will be installed on vCenter Server with the Neutral Storage Service.
Figure 28.  Verifying That StorMagic Neutral Storage Service and StorMagic vCenter Integration Services Are Selected
7. Click 
Next and complete the final steps of the wizard. The StorMagic tab will appear in the data center on the Manage tab 
(Figure 29).
Figure 29.  Completed Installation
SvSAN
Synchronous Mirroring
Production
iSCSI/Mirror
iSCSI/Mirror
Hypervisor
VSA
VM
VM
VSA
Hypervisor
NSH
VM
VM