Cisco Cisco Gigabit Ethernet Switch Module (CGESM) for HP Technical References
2-296
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem Command Reference Guide
380265-002
Chapter 2 CGESM Switch Cisco IOS Commands
show errdisable detect
show errdisable detect
Use the show errdisable detect user EXEC command to display error-disabled detection status.
show errdisable detect [ | {begin | exclude | include} expression]
Syntax Description
Command Modes
User EXEC
Command History
Usage Guidelines
A displayed
gbic-invalid
error reason refers to an invalid small form-factor pluggable (SFP) module.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
are not displayed, but the lines that contain Output are displayed.
Examples
This is an example of output from the show errdisable detect command:
Switch> show errdisable detect
ErrDisable Reason Detection status
----------------- ----------------
udld Enabled
bpduguard Enabled
security-violatio Enabled
channel-misconfig Enabled
psecure-violation Enabled
vmps Enabled
loopback Enabled
pagp-flap Enabled
dtp-flap Enabled
link-flap Enabled
gbic-invalid Enabled
dhcp-rate-limit Enabled
unicast-flood Enabled
storm-control Enabled
ilpower Enabled
Note
Though visible in the output, the ilpower, storm-control, and unicast-flood fields are not valid.
| begin
(Optional) Display begins with the line that matches the expression.
| exclude
(Optional) Display excludes lines that match the expression.
| include
(Optional) Display includes lines that match the specified expression.
expression
Expression in the output to use as a reference point.
Release
Modification
12.2(25)SE1
This command was introduced.