Cisco Cisco Gigabit Ethernet Switch Module (CGESM) for HP Technical References

Page of 742
   
2-370
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem Command Reference Guide
380265-002
Chapter  2      CGESM Switch Cisco IOS Commands
show mls qos queue-set
show mls qos queue-set
Use the show mls qos queue-set user EXEC command to display quality of service (QoS) settings for 
the egress queues.
show mls qos queue-set [qset-id] [ | {begin | exclude | includeexpression]
Syntax Description
Command Modes
User EXEC
Command History
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output 
do not appear, but the lines that contain Output appear.nway
Examples
This is an example of output from the show mls qos queue-set command:
Switch> show mls qos queue-set
Queueset: 1
Queue   :        1       2       3       4
----------------------------------------------
buffers   :      25      25      25      25
threshold1:      100     200     100     100
threshold2:      100     200     100     100
reserved  :      50      50      50      50
maximum   :      400     400     400     400
Queueset: 2
Queue   :        1       2       3       4
----------------------------------------------
buffers   :      25      25      25      25
threshold1:      100     200     100     100
threshold2:      100     200     100     100
reserved  :      50      50      50      50
maximum   :      400     400     400     400
qset-id
(Optional) ID of the queue-set. Each port belongs to a queue-set, which defines 
all the characteristics of the four egress queues per port. The range is 1 to 2.
| begin
(Optional) Display begins with the line that matches the expression.
| exclude
(Optional) Display excludes lines that match the expression.
| include
(Optional) Display includes lines that match the specified expression.
expression
Expression in the output to use as a reference point.
Release
Modification
12.2(25)SE1
This command was introduced.