Cisco Cisco Gigabit Ethernet Switch Module (CGESM) for HP Technical References

Page of 742
   
2-426
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem Command Reference Guide
380265-002
Chapter  2      CGESM Switch Cisco IOS Commands
snmp-server host
snmp-server host 
Use the snmp-server host global configuration command to specify the recipient (host) of a Simple 
Network Management Protocol (SNMP) notification operation. Use the no form of this command to 
remove the specified host.
snmp-server host host-addr [informs | traps] [version {1 | 2c {auth | noauthpriv}] [vrf 
vrf-instance] {community-string [notification-type]}
no snmp-server host host-addr [informs | traps] [version {1 | 2c {auth | noauth | priv}] [vrf 
vrf-instancecommunity-string 
Syntax Description
host-addr
Name or Internet address of the host (the targeted recipient).
udp-port port
(Optional) Configure the User Datagram Protocol (UDP) port number of the 
host to receive the traps. The range is 0 to 65535.
informs | traps
(Optional) Send SNMP traps or informs to this host.
version 1 | 2c | 3
(Optional) Version of the SNMP used to send the traps.
These keywords are supported:
1—SNMPv1. This option is not available with informs.
2c—SNMPv2C.
3—SNMPv3. These optional keywords can follow the Version 3 keyword:
auth (Optional). Enables Message Digest 5 (MD5) and Secure Hash 
Algorithm (SHA) packet authentication.
noauth (Default). The noAuthNoPriv security level. This is the default 
if the [auth | noauth | priv] keyword choice is not specified.
priv (Optional). Enables Data Encryption Standard (DES) packet 
encryption (also called privacy).
Note
The priv keyword is available only when the cryptographic 
(encrypted) software image is installed.
vrf vrf-instance
(Optional) Virtual private network (VPN) routing instance and name for this 
host.