Cisco Cisco MGX 8880 Media Gateway Release Notes

Page of 27
 
12
Release Notes for Cisco MGX 8880 VXSM Software Release 5.4.21
OL-19207-01
  Release 5.3.00 Features and Enhancements
Initializing SFTP
Upgrading PXM software is not sufficient to initialize and enable the SFTP feature. You must initialize 
the sshd_config file and reset the MGX chassis. Because resetting a chassis can interrupt traffic, you 
should initialize SFTP before upgrading software so you don’t need to reset it later.
To initialize SFTP, perform the following steps:
Step 1
Initiate an FTP session with the PXM card.
Step 2
Change to the F:/SSHD directory.
Step 3
Get the sshd_conf file from the F:/SSHD directory.
Step 4
Append the line subsystem sftp sftp to the file.
Step 5
Put the sshd_conf file into the F:/SSHD directory.
Step 6
Proceed with the normal software upgrade procedure. Alternatively, enter the resetsys command to reset 
the chassis.
Note
The resetsys command interrupts all traffic on the MGX chassis.
Remote IP Management Connection Enhancements
You can manage an MGX 8850 node directly from an Ethernet or console port on the PXM, or you can 
configure a remote path to the PXM through a service module or route processor module. The following 
management paths are supported in prior releases:
AXSM or MPSM to PXM
RPM-XF or RPM-PR to PXM
Earlier releases supported intranode connections only, and you could only have one PVC between an 
RPM and PXM. Release 5.3.00 enhances the atm0 feature to internode connections, where an RPM on 
one MGX switch connects to PXMs on other MGX switches using PNNI. And now you can manage 
multiple PXMs from a single RPM.
Management Connection Limitations
The IP addresses of hosts accessing the MGX 8850 node are stored in a RAM cache. Because this cache 
has a limit of 50 entries, only 50 IP hosts can actively access the node at one time. New IP hosts are 
blocked until the cache clears (as result of inactivity from some hosts) to make room for new entries.
Multiple RPMs can connect to the same PXM, but each RPM can have only one connection to the PXM. 
This is because the PXM has a single atm0 address.
Note
If you are connected to the MGX switch using the RPM and accidentally delete the SPVC, the 
connection drops. To restore RPM access, you must re-add the SPVC using the console port or Ethernet 
port.