Cisco Cisco Customer Voice Portal 8.0(1)

Page of 561
Notes
Default
Substitution
Allowed
Single Setting
Value
Required
Type
Name (Label)
a maximum length of 210
characters. The Unified ICME
10 (callvar1 –
callvar10)
Server returns a name-value pair
for up to 10 Call Peripheral
Variables in a result. Any value
that is placed in callvar<n> from
a Call Studio script is returned
unchanged, if the Unified ICME
Script does not change it.
Call Peripheral variables created
upon the return of the Unified
Yes
Yes
No
String
Call Peripheral
Variables
ICME Label request, regardless
Return 1 – 10
of whether or not these variables
(callvarReturn1
are filled by the Unified ICME

callvarReturn10)
Script. You need two sets of these
variables to keep reporting the To
ICM Call Peripheral Variables
separate from what is returned
from Unified ICME.
External Call Context (ECC)
variables passed by the Studio
Yes
Yes
No
String Array
FromExtVXML0
- 3 (External
script to the Unified ICME
VXML 0 –
Server. Each variable is a string
External
VXML 3)
of name-value pairs, separated by
semicolons, for up to 4 external
VoiceXML variables. This setting
can be a maximum length of 210
characters.
External Call Context (ECC)
variables received from the
Yes
Yes
No
String Array
ToExtVXML0
- 4 (External
Unified ICME script. The Unified
VXML 0 –
ICME Server returns a string of
External
VXML 4)
name-value pairs, separated by
semicolons, for up to 5 external
VoiceXML variables.
The number of milliseconds the
transfer request waits for a
3000 (ms)
Yes
Yes
Yes
Integer
Timeout
response from the Unified ICME
Server before timing out.
Note: This value can only be
increased or decreased by
increments of 500 ms.
This setting can be a maximum
length of 210 characters. The
Yes
Yes
No
String
caller_input
(Caller Input)
Configuration and Administration Guide for Cisco Unified Customer Voice Portal Release 4.1(1)
231
Chapter 4: Writing Scripts for Unified CVP
Scripting for Unified CVP with Call Studio