Cisco Cisco Computer Telephony Integration Option 8.5 Troubleshooting Guide

Page of 70
 
Chapter 2      Resolutions to Common Problems
Incorrect Configuration of Peripheral ID or Peripheral Type During Server Install
2-4
Cisco ICM Software CTI OS Troubleshooting Guide Release 6.0(0)
From the client application machine, open a console window and attempt 
to ping the connect machines. If the system is configured correctly, the 
ping should 
If the ping succeeded then the problem may be that the CTI OS server is 
not running on either of the connect machines. Start the CTI OS server 
on those machines and restart the client application.
If the ping fails for both connect machines and the connect machine entries 
in the registry are not TCP addresses, the problem may be an inability to 
resolve the connect machine name into an IP address. 
Try to ping the IP addresses corresponding to the connect machine names 
configured in the registry. 
If the ping succeeds, your DNS server may be down or the "hosts" file on 
the client machine may map the hostname to an incorrect address. 
Replace the connect machine names in the registry with the associated IP 
addresses, restart the download machines, and restart the client 
application.
If pinging the IP address fails, then either the IP address is incorrect or the 
network connection between the client application and connected machine is 
down. Your TCP/IP network administrator should be able to help resolve this 
issue.
Incorrect Configuration of Peripheral ID or 
Peripheral Type During Server Install
When installing the CTI OS server, the system administrator must enter a 
Peripheral ID and Peripheral Type corresponding to the target peripheral. The 
server uses this information to determine which switch behavior to emulate. If the 
wrong Peripheral ID or Peripheral Type is entered during install, CTI OS may 
attempt to emulate the incorrect switch type or may emulate a generic switch type. 
This will result in incorrect button enablement on the client application. Since the 
client application randomly selects a configuration server each time the client 
application starts, symptoms of this problem may be sporadic if connection 
profile information is not consistent between configuration servers. Perform the 
following checks to determine where the problem lies: