Feature 
Description 
Physical dimensions 
Chassis height: 
●  84 in. (213.36 cm) with power shelves installed 
●  80 in. (203.2 cm) without power shelves installed 
Chassis width: 
●  23.6 in. (59.94 cm) 
Chassis depth: 
●  36 in. (91.44 cm) 
●  41.5 in. (105.41 cm), including cable-management system and front cover 
Weight: 
●  780 lb (355 kg) as shipped, chassis only with fan trays installed, no power shelves 
●  Approximately 1100 lb (500 kg) chassis ship weight including crate and pallet 
●  1630 lb (740 kg) chassis fully configured, using all card slots, power shelves, and cosmetics (estimated) 
Power 
●  Maximum power consumption when chassis is fully loaded with 8 fabric cards with traffic running: 3244W 
●  Maximum power consumption when chassis is fully loaded with 24 fabric cards with traffic running: 7660W 
●  Chassis power supply maximum output capacity: 8.8kW for DC power supply and 10kW for AC power supply 
Environmental conditions 
Storage temperature: 
–40 to 70°C (–40 to 158°F) 
Operating temperature: 
●  Normal: 5 to 40°C (41 to 104°F) 
●  Short-term: –5 to 50°C (23 to 122°F) 
Relative humidity: 
●  Normal: 5 to 85% 
●  Short-term: 5 to 90% but not to exceed 0.024 kg water/kg of dry air 
Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year 
(this refers to a total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period). 
Approvals and Compliance 
Table 2 gives compliance and agency approvals for the Cisco CRS-3 24-Slot FCC. 
Table 2. 
Compliance and Agency Approvals 
Feature 
Description 
Safety Standards 
●  UL/CSA/IEC/EN 60950-1 
●  IEC/EN 60825 Laser Safety 
●  ACA TS001 
●  AS/NZS 60950 
●  FDA-Code of Federal Regulations Laser Safety 
EMI 
●  FCC Class A 
●  ICES 003 Class A 
●  AS/NZS 3548 Class A 
●  CISPR 22 (EN55022) Class A 
●  VCCI Class A 
●  BSMI Class A 
●  IEC/EN 61000-3-2: Power Line Harmonics 
●  IEC/EN 61000-3-3: Voltage Fluctuations and Flicker 
Immunity (Basic Standards) 
●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV contact, 15-kV air) 
●  IEC/EN-61000-4-3: Radiated Immunity (10 V/m) 
●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV power, 1-kV signal) 
●  IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM) 
●  IEC/EN-61000-4-5: Signal Ports (2-kV CM and 1-kV DM) 
●  IEC/EN-61000-4-5: Surge DC Port (1 kV) 
●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10 Vrms) 
●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30 A/m) 
●  IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations 
ETSI and EN 
●  EN300 386: Telecommunications Network Equipment (EMC) 
●  EN55022: Information Technology Equipment (emissions) 
●  EN55024: Information Technology Equipment (immunity) 
●  EN50082-1/EN-61000-6-1: Generic Immunity Standard