Description  
Environmental Conditions 
  Storage temperature: –40 to 70°C (–40 to 158°F) 
  Operating temperature: 
 
Normal: 5 to 40°C (41 to 104°F) 
 
Short-term: –5 to 50°C (23 to 122°F) short term 
  Relative humidity: 
 
Normal: 5 to 85% 
 
Short-term: 5 to 90% but not to exceed 0.024 kg water/kg of dry air 
Short-term refers to a period of not more than 96 consecutive hours and a total of 360 hours but not more 
than 15 instances in 1 year. 
Approvals and Compliance 
Table 2 gives standards compliance information about the Cisco CRS-1 4-Port 10GE Tunable WDMPHY Interface 
Module, and Table 3 lists optical specifications.  
Table 2. 
Compliance and Agency Approvals 
Feature  
Description  
Safety Standards 
  UL/CSA/IEC/EN 60950-1 
  IEC/EN 60825 Laser Safety 
  ACA TS001 
  AS/NZS 60950 
  FDA – Code of Federal Regulations Laser Safety 
EMI 
  FCC Class A 
  ICES 003 Class A 
  AS/NZS 3548 Class A 
  CISPR 22 (EN55022) Class A 
  VCCI Class A 
  BSMI Class A 
  IEC/EN 61000-3-2: Power Line Harmonics 
  IEC/EN 61000-3-3: Voltage Fluctuations and Flicker 
Immunity (Basic Standards) 
  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV contact, 15-kV air) 
  IEC/EN-61000-4-3: Radiated Immunity (10V/m) 
  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV power, 1-kV signal) 
  IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM) 
  IEC/EN-61000-4-5: Signal Ports (1 kV) 
  IEC/EN-61000-4-5: Surge DC Port (1 kV) 
  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10 Vrms) 
  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) 
  IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations 
ETSI and EN 
  EN300 386: Telecommunications Network Equipment (EMC) 
  EN55022: Information Technology Equipment (Emissions) 
  EN55024: Information Technology Equipment (Immunity) 
  EN50082-1/EN-61000-6-1: Generic Immunity Standard 
Network Equipment Building 
Standards (NEBS) 
This product is designed to meet the following requirements (qualification in progress): 
  SR-3580: NEBS Criteria Levels (Level 3) 
  GR-1089-CORE: NEBS EMC and Safety 
  GR-63-CORE: NEBS Physical Protection