Cisco Cisco CRS-X Multishelf System Data Sheet

Page of 5
 
 
© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 5 
Feature 
Description 
OTN (G.709 
feature 
summary) 
●  ITU G.709 
●  Alarm reporting: Loss of signal (LOS), loss of OTN frame (LOF), and loss of OTN multiframe (LOM) 
●  OTU backward defect indication (OTU-BDI), Optical-channel Data Unit alarm indication signal (ODU-AIS), ODU open 
connection indication (ODU-OCI), ODU locked (ODU-LCK), ODU backward defect indication (ODU-BDI), ODU payload 
type identifier mismatch (ODU-PTIM), OTU signal fail (OTU_SF_BER), and OTU signal degrade (OTU_SD_BER) 
●  OTU_SF_BER and OTU_SD_BER alarms based on monitoring of OTU BIP errors with a user-configurable threshold 
crossing 
●  Error counts: OTU Bit Interleaved Parity (BIP), OTU Backward Error Indication (BEI), ODU BIP, and ODU BEI 
●  Threshold crossing alerts (TCAs) for OTU BIP errors (SM TCA) and ODU BIP errors (PM-TCA) with user-configurable 
threshold 
●  Local (internal) and line (network) loopback 
Performance 
●  400-Gbps line-rate throughput 
●  Maximum number of interface modules per chassis: 8 slots and 16 slots 
Reliability and 
availability 
●  Line-card online insertion and removal (OIR) support without affecting system 
Network 
management 
●  Cisco IOS XR Software CLI 
●  Simple Network Management Protocol (SNMP) 
●  XML interface 
●  CraftWorks Interface (CWI) 
●  Cisco Active Network Abstraction (ANA) 
Physical 
dimensions 
●  Occupies one-half slot on a Cisco CRS chassis 
●  Weight: 8.8 lb (4 kg) 
●  Height: 20.6 in. (52.2 cm) 
●  Depth: 11.2 in. (28.4 cm) 
●  Width: 1.8 in. (4.49 cm) 
Power 
Expected value: 
●  200-Gbps mode: <90 W 
●  400-Gbps mode: <120 W 
*
 Energy monitor functions allow real-time power monitoring of individual components, including PLIMs and line cards, fabric, 
and PRP through CLI beginning with Cisco IOS XR Software Release 5.1.1 
Environmental 
conditions 
Storage temperature: -40 to 158°F (-40 to 70°C) 
Operating temperature: 
●  Normal: 32 to 104°F (0 to 40°C) 
●  Short-term: 23 to 122°F (-5 to 50°C) 
Relative humidity: 
●  Normal: 5 to 85% 
●  Short-term: 5 to 90% but not to exceed 0.024 kg water per kg of dry air 
Short-term refers to a period of not more than 96 consecutive hours or a total of 360 hours but not more than 15 instances in 
1 year. 
Approvals and Compliance 
Table 2 provides the standards and compliance information for the Cisco CRS 2 port 100 Gigabit Ethernet and 5 
port 40 Gigabit Ethernet LAN/OTN Flexible Interface Module. 
Table 2. 
Compliance and Agency Approvals 
Feature 
Description 
Cisco CRS 2 port 100 Gigabit Ethernet and 5 port 40 Gigabit Ethernet LAN/OTN Flexible Interface Module 
Safety 
standards 
●  UL/CSA/IEC/EN 60950-1 
●  AS/NZS 60950.1 
●  IEC/EN 60825 Laser Safety 
●  FDA - Code of Federal Regulations Laser Safety