Cisco Cisco CRS-X Multishelf System Data Sheet

Page of 5
 
 
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 3 of 5 
Feature 
Description 
Power 
Expected value < 110W in 400-Gbps mode, <80W in 200-Gbps mode. 
Energy monitor functionality allows real-time power monitoring of each individual component: PLIMs and line 
cards, fabric, PRP through CLI beginning with IOS XR Release 5.1.1. 
Environmental conditions 
Storage temperature: -40 to 158°F (-40 to 70°C) 
Operating temperature: 
●  Normal: 41 to 104°F (5 to 40°C) 
●  Short-term: 23 to 122°F (-5 to 50°C) 
Relative humidity: 
●  Normal: 5 to 85% 
●  Short-term: 5 to 90% but not to exceed 0.024 kg water/kg of dry air 
Short-term refers to a period of not more than 96 consecutive hours and a total of not more than 15 days in 1 year. 
(This refers to a total of 360 hours in any given year, but no more than 15 occurrences during that 1-year period.) 
Approvals and Compliance 
Table 2 gives standards compliance information for the Cisco CRS 40x10 Gigabit Ethernet Interface Module. 
Table 2. 
Compliance and Agency Approvals 
Feature 
Description 
Safety standards 
●  UL/CSA/IEC/EN 60950-1, 2
nd
 ed, AM 1 
●  AS/NZS 60950.1 
●  IEC/EN 60825 Laser Safety 
●  FDA - Code of Federal Regulations Laser Safety  
EMI 
●  FCC Class A 
●  ICES 003 Class A 
●  AS/NZS CISPR 22 Class A 
●  CISPR 22 (EN55022) Class A 
●  VCCI Class A 
●  IEC/EN 61000-3-2: Power Line Harmonics 
●  IEC/EN 61000-3-3: Voltage Fluctuations and Flicker 
Immunity (basic standards) 
●  IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8-kV contact, 15-kV air) 
●  IEC/EN-61000-4-3: Radiated Immunity (10V/m) 
●  IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2-kV power, 1-kV signal) 
●  IEC/EN-61000-4-5: Surge AC Port (4-kV CM, 2-kV DM) 
●  IEC/EN-61000-4-5: Signal Ports (1 kV) 
●  IEC/EN-61000-4-5: Surge DC Port (1 kV) 
●  IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10 Vrms) 
●  IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m) 
●  IEC/EN-61000-4-11: Voltage Dips, Short Interruptions, and Voltage Variations  
ETSI and EN 
●  EN300 386: Telecommunications Network Equipment (EMC) 
●  EN55022: Information Technology Equipment (Emissions) 
●  EN55024: Information Technology Equipment (Immunity) 
●  EN50082-1/EN-61000-6-1: Generic Immunity Standard 
Network Equipment 
Building Standards (NEBS) 
This product is designed to meet the following requirements (qualification in progress): 
●  SR-3580: NEBS Criteria Levels (Level 3) 
●  GR-1089-CORE: NEBS EMC and Safety 
●  GR-63-CORE: NEBS Physical Protection