Funkwerk W150N 5530000036 User Manual

Product codes
5530000036
Page of 15
 
Page 10/15 
WLAN-Bridgelink-Bundle     
Order No.: 5510000226 
 
Description: The WLAN Bridge Link Bundle “Out-of-the-Box” is 
designed for wireless wireless bridging of radio links in outdoor 
environments. The Bundle contain all required components to 
setup a radio link by using the new  802.11n technology. The 
usage of the components is sense full for radio links with up to 6 
km distance. 
 
The follow components are contains: 
Quantity 
Order No. 
Description 
5510000165 
bintec W1002n (Indoor usage) 
600507 
0,5m RTNC plug N plug LMR400 
600499 
Surge Arrester N plug N jack 
5500000847 
6m N plug N jack LMR400 
5500000551 
ANT-N-20-5G Dual Polarization 
 
 
In case of free line of sight the following results are expected  
by using the following configuration.  
 
 
Configuration of the Access Point 
 
 
Distance 
PHY Rate 
Operation 
Band 
Number 
of Spatial 
Streams 
Bandwidth 
Transmit 
Power 
Allowed 
EiRP 
Minimum 
antenna 
height  
0,5 km 
300 Mbit/s 
5 GHz Outdoor 
40 MHz 
16 dBm 
1000 mW 
2 m 
1 km 
180 Mbit/s 
5 GHz Outdoor 
40 MHz 
14 dBm 
1000 mW 
3 m 
2 km 
120 Mbit/s 
5 GHz Outdoor 
40 MHz 
11 dBm 
1000 mW 
4 m 
4 km 
30 Mbit/s 
5 GHz Outdoor 
40 MHz 
11 dBm 
1000 mW 
4,5 m 
6 km 
14,4 Mbit/s 
5 GHz Outdoor 
20 MHz 
11 dBm 
1000 mW 
6 m 
 
 
Hints to improve the operating distance: 
-  Use shorter cables, to reduce the cable lost 
-  Use a antenna with higher gain 
-  Select 20 MHz bandwidth instead 40 MHz, or use only one stream.  
-   
Hints for installation: 
-  The link must be free from any obstacles (free line of sight). If necessary a different location must be 
used or the antenna height must be increased. 
-  The antenna connectors of the Access Point ANT1 and ANT2 are connected to the antenna. It makes 
no difference which antenna socket is used. The antenna connector ANT3 of the AP are not used for 
these application. 
-  The antenna or rather the antenna pole must be connected with 16 mm
2  
CU or more to the potential 
equalisation. The Surge Arrestor protect the AP and must connected to the grounding of the building 
with 1,5 mm
2  
CU or more. The Surge Arrestor must be inserted in both antenna cables, usually close 
to the place there the antenna cable leaving the building. In some cases it is advisable to consult a 
specialist for lighting protection.