Intel Itanium 9340 LW80603003240AA User Manual
Product codes
LW80603003240AA
Thermal Specifications
96
Intel
®
Itanium
®
Processor 9300 Series Datasheet
contains dimensions for the thermocouple location on the Intel Itanium
processor 9300 series package. This is the recommended location for the placement of
a thermocouple for case temperature measurement.
a thermocouple for case temperature measurement.
Note:
Refer to the Package Mechanical Drawings in
.
5.3
Storage Conditions Specifications
Environmental Storage Condition limits define the temperature and relative humidity
limits to which the device is exposed to while being stored. The specified storage
conditions are for component level prior to installation onto board.
limits to which the device is exposed to while being stored. The specified storage
conditions are for component level prior to installation onto board.
Non operating storage condition limits for the component once installed onto the
application board are not specified. Intel does not conduct component level certification
assessments post subsequent applications such as components sub-assembly (FRU:
Field Replaceable Unit), or installation onto a board given the multitude of attach
methods, and board types used by customers. Provided as general guidance only,
Intel® board products are specified and certified to meet the following temperature
and humidity limits (Non-Operating Temperature Limit: -40°C to 70°C and Humidity:
50% to 90%, non condensing with a maximum wet bulb of 28°C).
application board are not specified. Intel does not conduct component level certification
assessments post subsequent applications such as components sub-assembly (FRU:
Field Replaceable Unit), or installation onto a board given the multitude of attach
methods, and board types used by customers. Provided as general guidance only,
Intel® board products are specified and certified to meet the following temperature
and humidity limits (Non-Operating Temperature Limit: -40°C to 70°C and Humidity:
50% to 90%, non condensing with a maximum wet bulb of 28°C).
Table specifies absolute maximum and minimum storage temperature limits which
represent the maximum or minimum device condition beyond which damage, latent or
otherwise, may occur. The table also specifies sustained storage temperature, relative
humidity, and time-duration limits. These limits specify the maximum or minimum
device storage conditions for a sustained period of time. At conditions outside
sustained limits, but within absolute maximum and minimum ratings, quality &
reliability may be affected.
represent the maximum or minimum device condition beyond which damage, latent or
otherwise, may occur. The table also specifies sustained storage temperature, relative
humidity, and time-duration limits. These limits specify the maximum or minimum
device storage conditions for a sustained period of time. At conditions outside
sustained limits, but within absolute maximum and minimum ratings, quality &
reliability may be affected.
Figure 5-2. Intel Itanium Processor 9300 Series Package Thermocouple Location
Not to scale.
Substrate
CL
IHS
CL
Thermocouple
Attach Point
Attach Point
1.5 mm
Substrate
CL