Intel E7210 LF80564QH0568M Data Sheet

Product codes
LF80564QH0568M
Page of 142
Thermal Specifications
102
Document Number: 318080-002
3.
Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the 
maximum power that the processor can dissipate. TDP is measured at maximum T
CASE
.
4.
These specifications are based pre-silicon estimates and simulations. These specifications will be updated 
with characterized data from silicon measurements in a future release of this document.
5.
Power specifications are defined at all VIDs found in 
. The Dual-Core Intel® Xeon® Processor 
7200 Series may be shipped under multiple VIDs for each frequency.
6.
FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor 
frequency requirements. 
6.1.2
Thermal Metrology
The minimum and maximum case temperatures (T
CASE
) are specified in 
through 
, and are measured at the geometric top center of the processor 
 illustrates the location where T
CASE
 
temperature measurements should be made. For detailed guidelines on temperature 
measurement methodology, refer to the Dual-Core Intel® Xeon® Processor 7200 
Series  and Quad-Core Intel® Xeon® Processor 7300 Series Thermal / Mechanical 
Design Guide
.
Table 6-8.
Dual-Core Intel® Xeon® Processor 7200 Series Thermal Profile
Power (W)
T
CASE_MAX
 (° C)
0
45.0
10
47.4
20
49.8
30
52.1
40
54.5
50
56.9
60
59.3
70
61.7
80
64.0