Cisco Cisco ASA 5510 Adaptive Security Appliance Leaflet

Page of 1264
 
3-10
Cisco ASA Series 명령 참조 , S 명령
  
3      show as-path-access-list through show auto-update 명령              
  show asp drop
Name: mp-svc-bad-length
SVC Module received bad data length:
    This counter will increment when the security appliance receives a packet from an SVC 
or the control software where the calculated and specified lengths do not match.
Recommendation:
    This indicates that a software error should be reported to the Cisco TAC. The SVC or 
security appliance could be at fault.
Syslogs:
    722037 (Only for SVC received data).
----------------------------------------------------------------
Name: mp-svc-unknown-type
SVC Module received unknown data frame:
    This counter will increment when the security appliance receives a packet from an SVC 
where the data type is unknown.
Recommendation:
    Validate that the SVC being used by the client is compatible with the version of 
security appliance software.
Syslogs:
   None.
----------------------------------------------------------------
Name: mp-svc-addr-renew-response
SVC Module received address renew response data frame:
    This counter will increment when the security appliance receives an Address Renew 
Response message from an SVC. The SVC should not be sending this message.
Recommendation:
    This indicates that an SVC software error should be reported to the Cisco TAC.
Syslogs:
   None.
----------------------------------------------------------------
Name: mp-svc-no-prepend
SVC Module does not have enough space to insert header:
    This counter will increment when there is not enough space before the packet data to 
prepend a MAC header in order to put the packet onto the network.
Recommendation:
    This indicates that a software error should be reported to the Cisco TAC.
Syslogs:
   None.
----------------------------------------------------------------
Name: mp-svc-no-channel
SVC Module does not have a channel for reinjection:
    This counter will increment when the interface that the encrypted data was received 
upon cannot be found in order to inject the decrypted data.
Recommendation:
    If an interface is shut down during a connection, this could happen; re-enable/check 
the interface. Otherwise, this indicates that a software error should be reported to the 
Cisco TAC.