Intel AT80604004881AA User Manual

Page of 172
Intel® Xeon® Processor 7500 Datasheet, Volume 1
119
Thermal Specifications
6.1.2
Thermal Metrology
The minimum and maximum case temperatures (T
CASE
) are specified in 
through 
, and are measured at the geometric top center of the processor 
substrate, not IHS, as in previous products
 illustrates the location where 
T
CASE
 temperature measurements should be made. For detailed guidelines on 
temperature measurement methodology, refer to the Intel® Xeon® Processor 7500 
Series Thermal and Mechanical Design Guide
.
Note:
Figure is not to scale and is for reference only.
75
65.4
80
66.6
85
67.7
90
68.9
95
70.0
Table 6-4.
95W TDP Processor Thermal Profile Table (Sheet 2 of 2)
Power (W)
T
CASE_MAX
 (°C)
Figure 6-4. Case Temperature (T
CASE
) Measurement Location
TBD